How to access the CCI air quality data
We have several AirGradient indoor and outdoor air quality sensors at the Greencoat building, which log data every 30 seconds via MQTT and are available to students and staff who want to access this data.
MQTT Server
The MQTT server sits at mqtt.cci.arts.ac.uk
on port
.18331883
The read-only student username and password can be provided by asking on Slack in the #technical channel.
Data format
The data format is airgradient/readings/(sensor)
, the sensors is the MAC address and serial number of that location, the locations are:
Greencoat
- GB_G03 = 0cb815082660
- GB_G04 = 4022d8f9b4d8
Peckham Road
- PR_B501-01 = dc5475bb845c
- PR_B501-02 = b48a0a613900
- PR_B501-03 = dc5475bcc430
High Holborn
- HH_302 = dc5475bce770
- HH_308 = dc5475bacb84
Example data:
{
"firmware":"9.3.0",
"wifi":-39,
"ssid":"UAL-IoT",
"light":4095,
"hwVersion":8,
"rco2":409,
"atmp":31.2,
"rhum":31.55,
"tvoc_index":164,
"nox_index":1,
"pm003_count":544,
"pm01":2,
"pm02":2,
"pm10":2,
"boot":1537,
"wdog":1
}
Subscribing to the data
In order to view the data in something like a GUI you need to subscribe with a wildcard such as airgradient/#
the default subscription for apps like MQTT Explorer shown below is just #
however the permissions of the student account only allow you to view the data inside airgradient
, sensors
.
If you wanted just 1 sensor, you could subscribe to airgradient/sensors/(sensor)
where sensor is one of the sensors listed in the sections above.